DuraLast Robin Hood Air Boosters

Robin Hood Air Boosters

Give your Central Heat and Air system a boost with the top air booster on the market. The Robin Hood Air Booster installs easily into your ducts to increase air flow to under served areas. This is an energy efficient, cost-effective way to make your home more comfortable year-round.

Swipe left to see more
 

All Robin Hood Air Boosters are made in the USA with top quality American components. Heavier gauged tubes, aluminum blades (except on the RH-6 which comes with plastic blades) and electrical motors all come standard. Robin Hood Air Boosters are easy to install and come with a one-year system warranty.

The Robin Hood Air Booster makes your heating and cooling system more effective by evening out airflow across the entire house.

Benefits include:

  • Offers additional free heating in the winter and free air conditioning in the summer

  • Solves the problem of hard-to-heat or cool rooms

  • Installation is easy, it fits any size or shape duct

  • Adds up to 1500 CFM in the summer, which can mean 3.75 tons more air conditioning

  • Can add an additional 113,000 BTUs of heat in the winter


What are the differences between the air booster models?

The chart below shows the specifications for each unit.
 

Model #

RH-6

RH-8

RH-10

RH-12

RH-14

Dimensions

7-1/4" x 6"

7-1/4" x 8"

8" x 10"

8-3/4" x 12"

8-3/4" x 14

Shipping Weight

2.75lbs

3.5lbs

4lbs

7lbs

7.5lbs

Fan (4-5 Blade)

5-3/4"

7"

8-3/4"

11"

12"

CFM (Free Air)

240

420

650

1150

1500

Voltage

120VAC

120VAC

120VAC

120VAC

120VAC

Cycle

60Hz

60Hz

60Hz

60Hz

60Hz

Watts

37

37

35

91

79

Amps

0.64 max

0.64 max

0.43 max

1.00 max

1.00 max

Certified for use at Max Temp

167F

167F

167F

167F

167F

Swipe left to see more
 

What kinds of places can I use the Robin Hood Air Booster?


The Robin Hood Air Booster can be used in a number of applications:

  • Additional heating and cooling to rooms that don’t get proper air-flow
  • Push hot air from a heat exchanger through a duct to a nearby room
  • Move excess hot air over a stove through a ceiling duct to another room
  • Thru-wall heat transfer to push heat to an adjacent room
  • Boost return air to gravity flow furnaces
  • More effective flow for wood heated homes
  • Radon reduction
  • Movie theater venting
  • Workshops
  • Garages
  • Add-on Rooms
  • Small Offices
  • Computer Rooms
When you have one or several rooms to cool or heat, let Robin Hood Air Boosters keep you comfortable with no additional cost!
 
Swipe left to see more
 

How do I install a Robin Hood Air Booster?
 

TOOLS REQUIRED:

  • Screwdriver

  • ½" and â…›" drill bits for sheet metal drill

  • Sheet metal shears or saw to cut metal duct

  • Junction box if required by local code

ENCLOSED PARTS:

  • (8) OF 5/32" sheet metal screws

  • 2 wire connectors

  • Paper templates indicating where to cut existing duct work and locating proper position for drilling holes

GENERAL INSTRUCTIONS:

The ROBIN HOOD Air Booster is designed to increase air flow of both hot and cold air in any forced air duct system. It will put more hot and cold air in any room you designate and can be installed to operate only when you want it, thus saving energy. It is installed in the branch duct serving the individual room (not the main supply duct) and performs best when installed near the outlet end of the branch duct. It is available in various size diameters so that it can be installed in ducts most common dimensions (6", 8", 10", 12", and 14"). The housing of ROBIN HOOD is made of standard galvanized duct material with a female receptacle collar on the incoming end and a male "crimped" collar on the outgoing end so that it can be fitted right into a cutout section of standard round duct. Installation can be made easily in round, square, and rectangular ducts by following these simple instructions: (see figure 1 below)

 

install-fig1
Swipe left to see more

ROUND DUCTS

(with the same diameter as ROBIN HOOD) (see figure 2)
Separate the existing system at a joint.

 

Model#

HR-6

HR-8

HR-10

HR-12

HR-14

Cut off from the female end

5¼"

5¼"

6

Swipe left to see more


 

install-fig2
Swipe left to see more

Install the ROBIN HOOD in the space provided with the fan blades facing the room to be serviced. (See figure 2) if separating at a joint is not practical, separate wherever desired in the branch duct.   You must "crimp" or make a series of 1" slits in the end of the cut duct closest to the main blower so that it can be tapered to fit into the female collar of ROBIN HOOD.  The male crimped end of ROBIN HOOD will fit right into the other side of the cut section, closest to the room. (See figure3)  Secure your ROBIN HOOD by wrapping duct tape around both ends.

install-fig3
Swipe left to see more

TO INSTALL FLEX DUCT

Simply slide the flex duct over each side of ROBIN HOOD and secure with duct tape or plastic straps.  Support flex duct with sheet metal straps or hanger wire.   Fan blades should be closest to room register.

 

install-fig4
Swipe left to see more


 

install-fig5
Swipe left to see more


 

ELECTRICAL CONNECTION

The ROBIN HOOD should be connected to 115 volt power source only. The installation kit comes equipped for flexible cord connection, which may not be acceptable by local authorities. To conform to local codes it may be necessary to attach a junction box at the point where the wires extend through the duct. Where ROBIN HOOD is installed as part of a heating duct system, electrical supply connections should be suitable for 75°C. temperature

POWER CONTROL OPTIONS:

  1. Connect directly to 115V for continuous operation.

  2. Wire through an ON/OFF switch located in a convenient place.
    (example: A wall switch in the room to be served)

  3. Wire through a thermostat installed in the room to be served.
    (this provides for automatic on/off room temperature control)

  4. Wire in parallel to existing blower. Be sure motor is rated 115 VAC, single phase 60 cycles. Blower motor controller cannot be variable speed tap type, solid state speed control or any other type not designated for dual motor control.

  5. Wire to 115V through an auxiliary switch, (pressure or "sail" type) which will automatically energize ROBIN HOOD whenever blower operates.

    Our Robin Hood Air Boosters generally ship from stock and can usually ship same day if ordered by 2:00pm EST. To shop all our DuraLast products, including the Robin Hood Air Booster, and all PolyLast and Hog's Hair Filters, click the button below.