Honeywell C6097A3095 Pressure Switch Break on Fall Manual Reset 0.4" to 5.0" W.C. Honeywell C6097A3095 Pressure Switch Breaks N.O. On Pressure Fall Edit Images - Honeywell C6097A3095 Pressure Switch Break on Fall Manual Reset 0.4" to 5.0" W.C. Honeywell C6097A3095 Pressure Switch Break on Fall Manual Reset 0.4" to 5.0" W.C.

Honeywell C6097A3095 Pressure Switch Break on Fall Manual Reset 0.4" to 5.0" W.C.

SKU: C6097A3095
Rating:
Quantity Price Stock
122
Usually Ships 3 - 10 Business Days
$249.25     /ea
122

The C6097A3095 found on this page, is a direct replacement for the following obsolete item(s):

Obsolete Product SKU
Honeywell C6097A1095 Pressure Switch 1/4" NPT Break on Fail Manual Reset 0.4" to 5.0" W.C. C6097A1095

Brand Honeywell
Honeywell C6097A1095 Pressure Switch 1/4" NPT Break on Fail Manual Reset 0.4" to 5.0" W.C.
Honeywell C6097A1228 Pressure Switch Flanged Break on Fail Manual Reset 0.4" to 5.0" W.C. C6097A1228

Brand Honeywell
Honeywell C6097A1228 Pressure Switch Flanged Break on Fail Manual Reset 0.4" to 5.0" W.C.
0
$0.00
0
$0.00
0
C6097A3095
Honeywell C6097A3095 Pressure Switch Break on Fall Manual Reset 0.4" to 5.0" W.C. 

The pressure switch monitors extremely low pressure differentials and triggers switch-on, switch-off or switch-over operations if a set switching point is reached. The switching point can be adjusted using a hand wheel. The pressure switch monitors positive and negative gas pressures on various industrial gas and air appliances, such as boiler fan monitoring and differential pressure monitoring in firing, ventilation and air-conditioning systems. Pressure switch C6097A switches in the event of decreasing pressure, C6097B switches in the event of increasing pressure

Adjusting Range: 0.4-4 W.C (1-10 mbar)
Maximum Inlet Pressure with Venting Line: 8.5psi (600 mbar)
Maximum Inlet Pressure without Venting Line: 7psi (480 mbar)
Lock-off: Yes
Difference between switching pressure and possible reset: 0.16-0.4 W.C (0.4-1 mbar)
Medium: Air/Gas
NPT Connection: 1/4"
Switching properties at setpoint value: NO-to-COM connection is interrupted if the pressure drops
Handwheel Setting/Switching Point: Hand wheel set to decreasing pressure/C6097 switches with falling pressure and locks off
Positive Pressure: Gas, Air, Flue Gas or Biogas
Negative Pressure: Air, Flue Gas
Electrical Connection: Screw Terminals and 1/2" NPT conduit